Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Transl Med ; 8(12): 785, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32647710

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) performed by intensivists is increasingly used in critically ill patients. However, TEE is usually not the preferred monitoring tool, especially when transthoracic echocardiography (TTE) appears to have addressed the clinical problems. As a result, it remains largely unknown whether TEE is a clinically valuable replacement or supplement for TTE as a primary tool in evaluating haemodynamic problems in critically ill surgical patients. The purpose of this study was to assess the diagnostic and therapeutic value of TEE instead or in addition to TTE in critically ill surgical patients with hemodynamic instability. METHODS: A prospective observational study was conducted. A total of 68 consecutive patients were enrolled from December 2016 to February 2018. TEE was routinely performed in addition to TTE, and the imaging data from TTE and TEE were successively disclosed to two different primary physicians, who reported any resulting changes in management. The two physicians were required to reach a consensus if there was any disagreement. The results of the additional TEE examination were compared with the clinical findings and TTE information. The image quality of TTE views was classified as a good (score 2), suboptimal (score 1) or poor view (score 0). According to the scores of TTE images, the patients were divided into two groups: patients with adequate TTE views (score ≥6) and inadequate TTE views (score <6). RESULTS: The results of additional TEE examination were classified into four categories. TEE failed to provide additional information about the initial diagnosis and therapy (class 1) in 26 patients (38.2%). Of the remaining 42 patients (61.8%), TEE instead or in addition to TTE revealed new findings or led to significant changes in therapy, as TTE supplied inadequate information. TEE used in addition to TTE led to a new diagnosis without therapeutic implications (class 2) in 11 patients (16.2%) and made a major clinical contribution leading to a therapeutic change (class 3) in 23 patients (33.8%). TEE used instead of TTE determined the diagnosis and therapy in 8 patients (11.8%) whose haemodynamic problems could not be addressed by TTE (class 4). In total, TEE had critical therapeutic benefits (class 3 and 4) that was not provided by TTE in 31 patients (45.6%). Of particular concern was that TEE had a higher proportion of therapeutic benefits to patients with inadequate TTE views than those with adequate TTE views (54.3% vs. 27.3%, P=0.036). CONCLUSIONS: TEE as a feasible clinical tool is useful for critically ill surgical patients with hemodynamic instability, especially for the patients with inadequate TTE views. TEE instead or in addition to TTE could provide valuable information for diagnosis, which may bring significant therapeutic benefits.

2.
Chin Med J (Engl) ; 131(3): 253-261, 2018 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-29363638

RESUMO

BACKGROUND: Passive leg raising (PLR) represents a "self-volume expansion (VE)" that could predict fluid responsiveness, but the influence of systolic cardiac function on PLR has seldom been reported. This study aimed to investigate whether systolic cardiac function, estimated by the global ejection fraction (GEF) from transpulmonary-thermodilution, could influence the diagnostic value of PLR. METHODS: This prospective, observational study was carried out in the surgical Intensive Care Unit of the First Affiliated Hospital of Sun Yat-sen University from December 2013 to July 2015. Seventy-eight mechanically ventilated patients considered for VE were prospectively included and divided into a low-GEF (<20%) and a near-normal-GEF (≥20%) group. Within each group, baseline hemodynamics, after PLR and after VE (250 ml 5% albumin over 30 min), were recorded. PLR-induced hemodynamic changes (PLR-Δ) were calculated. Fluid responders were defined by a 15% increase of stroke volume (SV) after VE. RESULTS: Twenty-five out of 38 patients were responders in the GEF <20% group, compared to 26 out of 40 patients in the GEF ≥20% group. The thresholds of PLR-ΔSV and PLR-Δ cardiac output (PLR-ΔCO) for predicting fluid responsiveness were higher in the GEF ≥20% group than in the GEF <20% group (ΔSV: 12% vs. 8%; ΔCO: 7% vs. 6%), with increased sensitivity (ΔSV: 92% vs. 92%; ΔCO: 81% vs. 80%) and specificity (ΔSV: 86% vs. 70%; ΔCO: 86% vs. 77%), respectively. PLR-Δ heart rate could predict fluid responsiveness in the GEF ≥20% group with a threshold value of -5% (sensitivity 65%, specificity 93%) but could not in the GEF <20% group. The pressure index changes were poor predictors. CONCLUSIONS: In the critically ill patients on mechanical ventilation, the diagnostic value of PLR for predicting fluid responsiveness depends on cardiac systolic function. Thus, cardiac systolic function must be considered when using PLR. TRIAL REGISTRATION: Chinese Clinical Trial Register, ChiCTR-OCH-13004027; http://www.chictr.org.cn/showproj.aspx?proj=5540.


Assuntos
Débito Cardíaco/fisiologia , Hidratação , Coração/fisiopatologia , Hipovolemia/diagnóstico , Posicionamento do Paciente , Sístole , Adulto , Idoso , Feminino , Hemodinâmica , Humanos , Hipovolemia/fisiopatologia , Unidades de Terapia Intensiva , Perna (Membro) , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Estudos Prospectivos , Respiração Artificial , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...